Brocade Fabric Watch Administrator's Guide (53-1000243-01, November 2006)
3-12 Fabric Watch Administrator’s Guide
Publication Number: 53-1000243-01
Configuring Fabric Watch Thresholds
3
Figure 3-4 shows how to select the custom settings for the threshold alarm level for the RXPerformance
area. The options are either to accept the default settings or provide custom settings.
Figure 3-4 Changing the Threshold Alarm level
1 : change behavior type 11 : change threshold alarm level
2 : change behavior interval 12 : change changed alarm
3 : change threshold boundary level 13 : change belowalarm
4 : change custom unit 14 : change abovealarm
5 : change custom timebase 15 : change inBetween alarm
6 : change custom low 16 : apply threshold alarm changes
7 : change custom high 17 : cancel threshold alarm changes
8 : change custom buffer 18 : return to previous page
9 : apply threshold boundary changes
10 : cancel threshold boundary changes
Select choice => : (1..18) [18]11
1 : Default
2 : custom
Enter alarm level type => : (1..2) [1] 2
Index ThresholdName BehaviorType BehaviorInt
216 eportRXPerf216 Triggered 1
217 eportRXPerf217 Triggered 1
218 eportRXPerf218 Triggered 1
219 eportRXPerf219 Triggered 1
220 eportRXPerf220 Triggered 1
221 eportRXPerf221 Triggered 1
222 eportRXPerf222 Triggered 1
223 eportRXPerf223 Triggered 1
Threshold boundary level is setat : Custom
DefaultCustom
Unit Percentage(%) Percentage(%)
Time base minuteminute
Low 0 0
High 100 80
BufSize 0 0
Threshold alarmlevel is set at: Custom
.
.
.