Configuring Fabric Watch Thresholds
3
Figure 3-2 shows how to change the threshold boundary level to custom so that the new custom value of
80 is the new trigger point.
Figure 3-3 shows how to apply the custom value; unless you apply the value, it does not take effect.
Figure 3-2 Changing the Threshold Boundary Level
Figure 3-3 Applying Threshold Boundary Changes
1 : change behavior type 11 : change threshold alarm level
2 : change behavior interval 12 : change changed alarm
3 : change threshold boundary level 13 : change belowalarm
4 : change custom unit 14 : change abovealarm
5 : change custom timebase 15 : change inBetween alarm
6 : change custom low 16 : apply threshold alarm changes
7 : change custom high 17 : cancel threshold alarm changes
8 : change custom buffer 18 : return to previous page
9 : apply threshold boundary changes
10 : cancel threshold boundary changes
Select choice => : (1..18) [18]3
1 : Default
2 : custom
Enter boundary level type => : (1..2) [1] 2
Index ThresholdName BehaviorType BehaviorInt
216 eportRXPerf216 Triggered 1
217 eportRXPerf217 Triggered 1
218 eportRXPerf218 Triggered 1
219 eportRXPerf219 Triggered 1
220 eportRXPerf220 Triggered 1
221 eportRXPerf221 Triggered 1
222 eportRXPerf222 Triggered 1
223 eportRXPerf223 Triggered 1
Threshold boundary level is set at : Custom.
.
.
.
1 : change behavior type 11 : change threshold alarm level
2 : change behavior interval 12 : change changed alarm
3 : change threshold boundary level 13 : change belowalarm
4 : change custom unit 14 : change abovealarm
5 : change custom timebase 15 : change inBetween alarm
6 : change custom low 16 : apply threshold alarm changes
7 : change custom high 17 : cancel threshold alarm changes
8 : change custom buffer 18 : return to previous page
9 : apply threshold boundary changes
10 : cancel threshold boundary changes
Select choice => : (1..18) [18]9.
.
.
N
ote
To ensure that your threshold setting configuration takes effect, remember to apply the threshold
boundary changes, and then change the threshold boundary level to Custom.