HP StoreEver MSL2024, MSL4048, MSL8048, and MSL8096 Tape Libraries User and Service Guide (AK378-96059, December 2012)

Table Of Contents
Table 47 Sub-codes for error BE
SolutionCauseMessageSub-code
Verify that the Extender is an
HP MSL Library Extender.
The Extender is not an HP MSL
Library Extender.
Extender personality not
matching.
51
Verify that the lower library is
an HP MSL2024 or MSL4048
tape library.
The lower library is not an HP
MSL2024 or MSL4048 tape
library.
Lower library personality not
matching.
52
Update the extended library
firmware with the current
firmware bundle, which will
update both libraries and the
Extender with compatible
firmware versions.
The firmware version of the
Extender is not compatible with
the firmware version of the master
library.
Extender firmware not matching.53
Disable extended mode, update
both libraries to the most recent
released versions, and then
re-enable extended mode.
The firmware versions of the
master library and lower library
are not compatible with each
other.
Lower library firmware level not
matching.
54
Verify that the master (top)
library is an MSL4048 or
MSL8096.
The master library is not an
MSL4048 or MSL8096.
Incompatible height form factor
for master library.
55
Verify that the lower library is
an MSL2024 or MSL4048.
The lower library is not an
MSL2024 or MSL4048.
Incompatible height form factor
for lower library.
56
Power cycle the master library.
(The master library will attempt
to download the Extender
firmware to the Extender when
the master library is powered
on.)
The firmware upgrade failed,
possibly because of a power
failure during the upgrade
operation.
Extender firmware corrupted57
Table 48 Sub error codes related to robotics errors during movement to extender position
MessageSub-code
Invalid stack configuration (1U cannot be the master or lower library)F0
Error during elevator home movementF1
Error during sled movement to home sensorF2
Error during sled movement to extender positionF3
Error during rotation movement to extender positionF4
Error during elevator movement to extender positionF5
Error during sled movement to rotate positionF6
Error during rotation movementF7
Error cartridge present sensor during cartridge transfer from robotics to extender carrier
(and reverse)
F8
Cartridge present sensor deviates from expected parameterF9
Error during first slider movement (movement with opened gripper) from/to extender
position
FA
Error during first gripper movement (open gripper) from/to extender positionFB
Error during second gripper movement (close gripper) from/to extender positionFC
Error codes 187