HP StoreEver MSL2024, MSL4048, MSL8048, and MSL8096 Tape Libraries User and Service Guide (AK378-96059, December 2012)

Table Of Contents
3. By using Previous or Next, you can select from the following information screens:
Serial number
Drive type
Firmware revision
SCSI ID (parallel SCSI tape drives only)
For a Fibre Channel tape drive, you can also select from the following information screens:
The WWide Node Name for the FC node to which the tape drive is connected.
The WWide Port Name and Port Type for Port A.
The WWide Port Name and Port Type for Port B.
World Wide names are assigned automatically; they cannot be configured.
Component status (Status/Information > Component Status)
To obtain component status:
1. From the Home screen, press Previous or Next until the screen displays Status/Information.
Press Enter to select.
2. Press Previous or Next until the screen displays Component Status. Press Enter to select.
3. By using Previous or Next, you can select from the following information screens:
Drive activity
Library status
Drives status
Fan status
The second line of the screen will display one of the following:
Good — the component is operating normally.
Warning — the component might have an issue that should be addressed. The device is
functional.
Critical — the component has an error condition that should be addressed. The device
may not be fully functional.
Failed — the component has a known failure and should be replaced.
Network information (Status/Information > Network Information)
To access network settings for the device:
1. From the Home screen, press Previous or Next until the screen displays Status/Information.
Press Enter to select.
2. Press Previous or Next until the screen displays Network Information. Press Enter to select.
3. Press Previous or Next to access the following information:
IPv4 Network Enabled or Disabled
IPv6 Network Enabled or Disabled
Host Name
Domain Name
MAC Address
4. For IPv4 Network or IPv6 Network, press Enter and then use Previous or Next to access the
network addresses and configuration.
MSL2024 Operator control panel (OCP) 107