HP StorageWorks 1510i Modular Smart Array Firmware v1.32 Release Notes (441888-001, January 2007)
Version
1.32
Description
The MSA1510i controller firmware has b een updated to version 1 .32.
Update recommendation: Recommended
Supersedes: MS A15010i firmware version 1.30.
Product mode
ls
HP StorageWorks 1510i Modular Smar t Array
Servers supported
For information on the servers that are supported on the MSA1510i, see the compatibility guide on the
Technical Documents page of the MSA151 0 i website: h
ttp://www.hp.com/go/msa1510i .
Operating
systems supported
• Microsoft Windows Server 2 003
• Microsoft Windows Server 2003 x64 Editions
• Microsof
t Windows Server 2003 Itanium-based Edition
• Microsoft Windows 2000
Enhancements
Supports installation of 750 GB hard drives in MSA20 storage enclosures.
Fixes
• Fixedac
ontroller hang due to a residual TCP segment error occurring when a non-Windows
based I/
Otoolwasused.
• Th e 750 GB drive reports as such. In e arlier firmware versions, the drive r eported as 539 GB.
• The configuration now clears from the Storage Management Utilit y (SMU).
• The con
troller no longer hangs during logical unit extensions.
• The overrun flag bit in the iSCSI header no longer causes Data Phase Error.
• R2T or Immed iate D ata PDU with 8 bytes no longer results in data integrity failure.
• Configu
ration can now migrate to the spare chassis.
• Show tech_support ouputs text from a remote telnet of SSH session works correctly.
• Show iscsi_keys in show tech_support works correctly.
• Fixed
a Lockup of F611 due to a 512K I/O request seen in a non-Windows setup.
• Removed the wrong status display of the Initiator not logged in from SMU. Status is available on
CLI and will be fixed in a future release of SMU .
• Fixed F613 Lockup caused by broadcast/multicast traffic on data ports.
• Fixe
dF081LockupwhenaccessedbySIM5.1.
1510i Modular Smart Array firmware v1.32
3