HP StorageWorks 1500 Modular Smart Array maintenance and service guide (356606-002, October 2006)

Message Type
Description Action
511 FIBRE CHANNEL
SUBSYSTEM HARDWARE
FAILURE
Error
The array controller's Fibre
Channel subsystem has
encountered a critical
error during the power up
sequence.
Remove the failed array
controller and its associated
Fibre Channel module,
reseat the Fibre Channel
daughter card on the array
controller, wait 10 seconds,
then reinsert the Fibre
Channel module and the
array controller, ensuring
that they are fully seated in
their respective bays in the
chassis.
Should the issue persist,
contact HP support.
513 UNCORRECTED ECC
MEMORY ERROR SEEN
Error
The array controller has
detected an uncorrectable
error in the ECC memory on
the memory cache board.
Remove the
failed array
controlle
randreplacethe
memory ca
che board with a
new one.
514 FIBRE SWITCH
HARDWARE FAILURE
Error
Theembeddedswitchinthe
Fibre Channel I/O bay is
not responding correctly or
is not working. (Please note
that some switches take
several minutes to start up.)
Remove the embedded
switch, wait 10 seconds,
and then reinsert the switch,
ensuring that it is fully seated
in the chassis.
Should the issue persist,
contact HP support.
515 FIBRE DEVICE
HARDWARE FAILURE
Error
The array controller
rmware does not
recognize the device in
the Fibre Channel I/O bay.
Thedevicehasfailedor
is not supported by the
installed rmware version.
Ifthedevicewasnotrecently
installed or the rmware was
not recently downgraded,
remove the embedded
device, wait 10 seconds,
and then reinsert the device,
ensuring that it is fully seated
in the chassis.
Should the issue persist,
contact HP support.
516 F
IBRE SUBSYSTEM
LINK
FAILURE
Erro
r
The c
ontroller is not currently
lin
ked to anything. This
cou
ld be due to the
fol
lowing:
Th
e Fibre Channel cable
is
not connected.
Th
edevicetowhichit
i
s connected is currently
n
ot working.
T
he MSA is connected
to a device that with an
incompatible port type.
Chec
ktheconnections
on b
oth ends of the Fibre
Cha
nnel cables and make
sur
ethattheswitch,hub,or
ot
her system that the bre is
co
nnected to is operating
pr
operly and is properly
c
ongured.
S
hould the issue persist,
c
ontact HP support.
517 FIBRE SUBSYSTEM
LINK OK
Informational
The Fibre Channel port has
transitioned to an online
state.
58