Message Type
Description Action
106 VOLUME #<n>
STATE WAITING TO
REBUILD
Informational The congured volume is
waiting to start rebuilding
data on a SCSI hard drive
that replaces a previously
failed drive. The rebuild
may not have started yet
because the array controller
is already performing
arebuildonanother
congured volume.
107 VOLUME #<n>
STATE WAITING TO
EXPAND
Informational The congured volume is
waiting to start a volume
expansion operation.
The expansion may have
notstartedyetbecause
another congured volume
is undergoing expansion or
a rebuild is occurring on
the con
gured volume.
108 VOLUME #<n>
STATE MISSING
DRIVES
Error
The congured volume is
missing too many of the
SCSI hard drives that it is
composed of, making it
unusable. The volume is
disabled.
Power off the MSA and
then all attached storage
enclosures. Unplug and
reinsert all SCSI hard drives
ensuring they are fully seated
in their bays. Check the
cables connecting the MSA
to any attached storage
enclosures. Power on the
attached enclosures and
then the MSA.
109 VOLUME #<n>
STATE WRONG DRIVE
REPLACED
Error
The congured volume
appears to have had
known, good SCSI hard
drives replaced instead of
known, failed hard drives.
The MSA should be powered
offandthegoodharddrives
should be restored while the
failed hard drives should be
replaced.
110 VOLUME #<n>
EXPANSION DISABLED
Informational
The
volume expansion
op
erationonthecongured
vo
lume has been disabled.
Th
is may be because
a
rebuild operation
i
s ongoing, another
e
xpansion is already
r
unning, or the cache
memory is disabled due
to a low battery. The
expansion will start once
the condition has been
cleared.
111 VOLUME #<n>
INITIALIZING PARITY
Informational
The array controller is
calculating and storing
parity information for the
congured volume and
therefore performance may
be lower until it completes.
50