HP Array Configuration Utility User Guide (416146-001, January 2006)

Scripting in ACU 42
Message Comment or explanation (if not self-explanatory)
Internal error.
An internal ACU error has occurred, and some error is not being
identified properly.
Invalid array accelerator setting.
The specified array accelerator setting is invalid or is not supported
with the current configuration.
Invalid array. The array ID is invalid.
Invalid ChassisName.
The entered ChassisName is invalid. Use characters from the set a–
z, A–Z, 0–9, !, @, #, *, (, ), ,, -, _, +, :, ., /, and [space]. The ID
cannot end with a space character or exceed the maximum number
of characters allowed by the controller.
Invalid
ClearConfigurationWithDataLoss
parameter.
Invalid Controller.
Invalid expand priority.
The specified expand priority is not supported, or the controller does
not allow expansion and, therefore, does not support the Expand
Priority feature.
Invalid license key.
Invalid logical drive. The logical drive ID is not valid.
Invalid Method. Invalid Method value.
Invalid physical drive.
The physical drive listed for the array is not a valid physical drive,
or it is a physical drive that is not capable of being placed in the
array.
Invalid Preferred Path.
The preferred path specified is not a valid chassis slot for an
available active controller, or the controller is not available.
Invalid Preferred Path Mode.
The preferred path mode is not a valid preferred path mode, or the
controller is not available.
Invalid RAID.
The specified RAID level is invalid or is not possible with the current
configuration.
Invalid read cache/write cache
ratio.
The specified cache ratio is not supported by either the controller or
the current controller configuration.
Invalid rebuild priority.
Invalid Sectors.
The specified MaxBoot setting is invalid or is not supported with the
current configuration.
Invalid Size.
The specified size is invalid or is not possible with the current
configuration.
Invalid Spare.
The spare drive listed for the array is not a valid spare drive, or it is
a drive that cannot be placed on the array as a spare.
Invalid SSP adapter ID.
Invalid SSP state.
Invalid stripe size.
The specified stripe size is either invalid, not supported with the
current RAID level, or not supported with the current configuration.
Invalid SurfaceScanDelay.
License key is not a controller
feature license key.
The entered license key is for a feature that the controller does not
support.
Logical drive not specified.
Some commands require a logical drive, but no logical drive is
specified in the script file.
More than one (text) command
cannot exist in the same section.
The specified command should be used only once per section.