Installation and Reference Guide for HP MPIO Full Featured DSM for MSA1000/1500 (Active-Active) Disk Arrays 3.00.00 (AA-RW8AD-TE, March 2008)

Installing HP MP
IO MSA DSM on cluster congurations
To install HP MP
IO MSA DSM on each member of a cluster conguration:
NOTE:
In a cluster conguration, HP MPIO MSA DSM must be installed on one cluster at a time.
1. Complete the pre-installation checklist (Table 2) and the p re-installation procedure.
2. Using Cluster Administrator :
Move all cluster shared storage to one server.
•PauseclusternodeA.
Disable failback for all groups containing resources managed by MSCS.
3. Install HP MPIO MSA DSM on node A by following step 2–8 from the procedure Installing HP MPIO
MSA DSM on stand-alone systems.
4. Using Cluster Administrator :
•UnpauseclusternodeA.
•PauseclusternodeB.
5. Install H P MPIO MSA DSM on node B, following step 2–8 from the procedure Installing HP MPIO
MSA DSM on stand-alone systems.
6. Using Cluster Administrator :
•UnpauseclusternodeB.
Restore failback as needed.
Redistribute LUNs.
Upgrading HP MPIO MSA DSM software
You can upgrade HP M PIO MSA DSM from an existing version to the current version on a stand-alone
system or cluster conguration..
This section describes how to upgrade H P MPIO MSA DSM on the following congurations:
Upgrading HP MPIO MSA DSM on stand-alone systems
Upgrading HP MPIO MSA DSM on cluster congurations
Upgrading HP M PIO MSA DSM on stand-alone systems
To upgrade HP MPIO MSA DSM from a previous version on stand-alone systems, complete the steps
below:
1. Complete the pre-installation checklist (Table 2) and the p re-installation procedure.
2. Run Launch.exe from the i nstallation location.
3. In the launch window, click HP MPIO Full Featured DSM for MSA1000/1500 (Active-Active) Disk
Arrays.
4. Select the upgrade option.
5. Follow the on-screen instructions to complete the upgrade.
6. Restart the server.
HP MPIO Full Featured DSM for MSA1000/1500 (Active-Active) Disk Arrays 3.00.00
13