Redundant Power Supply/Blower Assembly
The MSA1000 includes a redundant power supply. The redundant power supply is
identical to the primary supply and shares the electrical load equally. If either
supply fails or is removed, the other power supply assumes the full load without
interruption. Hot-pluggability allows you to replace the failed supply without
shutting the MSA1000 storage system down.
The MSA1000 includes a redundant blower. If one blower operates too slowly, or
completely shuts off, the other blower will begin to operate at a higher speed.
Any changes in the performance level of the power supply or blower are reported
on the LCD panel of the associated controller. For a description of the possible
informational and error messages associated with the power supplies or blowers,
see the definitions for messages numbered 400 through 499 in the HP
StorageWorks MSA1000 Controller User Guide.
Depending on the setup of Insight Manager 7 and System Event Analyzer,
informational and error messages about the power supplies and blowers are also
reported though these software components.
Figure 6 is an illustration of the power supply/blower assembly.
Figure 6: Power supply/blower assembly
Refer to the “Replacing a Power Supply” and “Replacing a Variable Speed
Blower” sections in the Operation and Management” chapter for more