HP StorageWorks Modular Smart Array (MSA1000) Controller User Guide (September 2003)

Controller Display Messages
41MSA1000 Controller User Guide
65 CACHE
HARDWARE ENABLED
Informational The cache hardware had
been temporarily disabled
but is now enabled again.
This may have been due to
insufficient charge on the
batteries that have now
charged up to capacity.
66 CACHE
HARDWARE FAILED
AND DISABLED
Error The cache memory has
experienced a hardware
failure.
If the failure has occurred
on the
standby
array
controller, then remove the
standby
array controller,
replace the cache modules,
wait 10 seconds, and then
reinsert the array controller
insuring that it is fully
seated in the chassis.
If the failure has occurred
on the
active
array
controller, then wait until
downtime is available.
Power off the MSA1000,
remove the array controller,
replace the cache modules,
and reinsert the array
controller insuring it is fully
seated in the chassis.
Should the issue persist
please contact HP support
67 CACHE
HARDWARE
TEMPORARILY
DISABLED
Informational The cache memory
hardware has temporarily
been disabled typically
because either the battery
is not charged up or a
capacity expansion
operation is occurring. The
cache will automatically be
enabled once the condition
has been corrected.
Table 3: LCD Message Descriptions
Message Type Description Action