HP StorageWorks Modular Smart Array (MSA1000) Controller User Guide (September 2003)

Controller Display Messages
38 MSA1000 Controller User Guide
49 REDUNDANCY
FAILED FIRMWARE
LOCKUP
Error While either attempting to
enter redundant mode or
already operating in
redundant mode, one of
the array controllers
encountered a critical
condition resulting in a
firmware lockup.
Redundancy is disabled at
this time.
If the MSA1000 is currently
involved in host I/O,
remove the
standby
array
controller, wait 10 seconds,
and then reinsert it insuring
that it is fully seated in the
chassis.
If this does not resolve the
issue then wait until
down-time is available.
Power off the MSA1000,
remove both array
controllers, and reinsert
them insuring they are fully
seated in the chassis.
Should the issue persist
please contact HP support.
50 REDUNDANCY
FAILED OUT OF
MEMORY
Error While either attempting to
enter redundant mode or
already operating in
redundant mode, one of
the array controllers failed
to allocate required
memory. Redundancy is
disabled at this time.
If the MSA1000 is currently
involved in host I/O,
remove the
standby
array
controller, wait 10 seconds,
and then reinsert it insuring
that it is fully seated in the
chassis.
If this does not resolve the
issue then you wait until
down-time is available.
Power off the MSA1000,
remove both array
controllers, and reinsert
them insuring they are fully
seated in the chassis.
Should the issue persist
please contact HP support.
Table 3: LCD Message Descriptions
Message Type Description Action