HP StorageWorks Modular Smart Array (MSA1000) Controller User Guide (September 2003)

Controller Display Messages
34 MSA1000 Controller User Guide
30 I2C READ
FAILURE <I2C
device name>
Error The MSA1000 has a
number of internal devices
that are accessed via an
I2C hardware bus. One of
these devices failed when
attempting to read from it.
Certain I2C devices are
considered critical and will
result in a failure of the
array controller while
others may result in some
loss of functionality (such
as lost display messages).
Should the issue persist
please contact HP support.
31 I2C WRITE
FAILURE <I2C
device name>
Error The MSA1000 has a
number of internal devices
that are accessed via an
I2C hardware bus. One of
these devices failed when
attempting to write to it.
Certain I2C devices are
considered critical and will
result in a failure of the
array controller while
others may result in some
loss of functionality (such
as lost display messages).
Should the issue persist
please contact HP support.
32 CHASSIS NVRAM
CONTENTS
CORRUPTED
Error The MSA1000 has
non-volatile memory on it
that contains required
information which is
needed to operate. This
non-volatile memory
appears to be corrupted
and the information is not
valid. The MSA1000
cannot continue to operate
and will halt.
Please contact HP support.
40 BEGIN
REDUNDANCY
SUPPORT
Informational The array controllers are
attempting to enter
redundant mode.
Table 3: LCD Message Descriptions
Message Type Description Action