HP StorageWorks 1000 Modular Smart Array maintenance and service guide (257547-003, October 2006)

Installing the c
omponent
1. Slide the replacement SCSI I/O module into the bay until it clicks into place.
15560
2. Reconnect all SCSI cables.
NOTE:
Ensure that all of the SCSI cable connectors are fastened tightly.
Verifying proper operation
After replacing the failed SCSI I/O module, verify that:
The module status LED is solid green.
No new error messages are displayed on the array controller LCD panel.
Replacing the power button module
CAUTION:
The power button module is not hot-pluggable. Before replacing the module, all I/O from the servers
must be stopped and the MSA must be powered down.
Before you begin
CAUTION:
Before r
emoving a component or blanking panel from an operational device, make sure that you
have th
e replacement part available. Removing a component or blank impacts the airow and
coolin
g ability of the device. To avoid possible overheating, insert the new or replacement component
withi
n one or two minutes. If the internal temperature exceeds acceptable limits, the device may
overheat and automatically shut down or restart.
Parts can be damaged by electrostatic discharge. Use proper anti-static protection.
maintenance and service guide
91