Message Type
Description Action
306 FIRMWARE FLASH
STARTED
Informational
The array controller in
the MSA has started the
firmware flash process.
Do not turn off power
to the system until it has
completed. This could take
several minutes.
307 FIRMWARE FLASH
DONE
Information
al
The array controller in the
MSA has completed the
firmware flash process. It is
nowsafetorestarttheMSA
and begin using the new
firmware. I
ndual-controller
configurat
ions, the new
firmware is cloned onto the
other controller during the
startup routine.
308 FIRMWARE FLASH
FAILED
Error
The array controller in
the MSA has failed the
firmware flash process.
Attempt the flash process
again.
Should the issue persist,
contact HP support.
309 EMU FLASH
STARTED
Informational
The EMU has started the
firmware flash process.
Do not turn off the power
to the system until it has
completed. This could take
five minutes.
310 EMU FLASH DONE
Infor
mational
The EMU has completed the
firmware flash process. It is
now safe to turn off power
to the system.
311 EMU FLASH
FAILED
Error
The EMU has failed the
firmware flash process.
Attempt the flash process
again.
Should the issue persist,
contact HP support.
312 FIRMWARE FLASH
STARTED ON BOX #<n>
Informational A firmware fl ash operation
has started on an attached
storage enclosure.
313
FIRMWARE FLASH
DO
NE ON BOX #<n>
Informational A firmware fl ash operation
has completed on an
attached storage enclosure.
Re
start the storage enclosure
to enable the new firmware.
314 FIRMWARE FLASH
FAILED ON BOX #<n>
Error
A firmware fl ash operation
has failed on an attached
storage enclosure.
Attempt the flash process
again.
Should the issue persist,
contact HP support.
400 STORAGE BOX
#<n> FAN OK
Informational A fan in the specified
storage enclosure that
was previously marked as
failed or degraded is now
operating normally.
401 STORAGE BOX
#<n> FAN FAILED
Error
Afaninthespecified
storage enclosure has
failed. The MSA may
now be susceptible to
overheating if corrective
action is not taken.
Check all fans and ensure
they are operating. Any
failed fans should be
replaced.
maintenance and service guide