HP StorageWorks 1000 Modular Smart Array maintenance and service guide (257547-003, October 2006)

Message Type
Description Action
112 VOLUME #<n>
REBUILD FAILURE
Error
The rebuild operation on
the congured volume has
failed.
If the volume is still operating
in regenerative mode,
remove the new SCSI hard
drive that was added as a
replacement for the original
failed hard drive and replace
it with a different new drive.
113 VOLUME #<
n>
EXPANSION FA
ILURE
Error
Thevolumeexpansion
operation on the congured
volume has f
ailed.
Open the Array
Conguration Utility (ACU)
or MSA Command Line
Interface (MSA-CLI) and use
it to determine the state of
thevolume. Ifthevolumeis
still operational, it is possible
to retry the operation.
114 VOLUME #<n>
STATE DELETED
Informational The congured volume has
been deleted and is no
longer available. Volumes
are deleted by using the
Array Conguration Utility
(ACU) or MSA Command
Line Interface (MSA-CLI).
115 VOLUME #<n>
MEDIA EXCHANGED
Informational All failed hard drives of the
specied volume have been
replaced by good hard
drives or all unplugged
hard drives in the volume
have been plugged back
in. This message should be
followed by message 02
ENABLE VOLUME <n>?
'<'=NO, '>'=YES.
See the entry for 02 ENABLE
VOLUME <n>? '<'=NO,
'>'=YES.
120 C
ONFIGURED
VOL
UMES <n>
Informational The specied number of
congured volumes was
detected at power-up.
121 NO VOLUMES
DETECTED
Informational No congured volumes
were detected at power-up.
If there are supposed to be
congured volumes, power
off the MSA and then all
attached storage enclosures.
Unplug and reinsert all SCSI
hard drives ensuring they
are fully seated in their bays.
Check the cables connecting
the MSA to any attached
storage enclosures. Power
on the attached enclosures
and then the MSA.
122 NEW VOLUME(S)
DETECTED
Informational Congured volumes from
another array controller
were migrated to this
array controller. The
conguration information
has been updated.
maintenance and service guide
49