HP StorageWorks 1000 Modular Smart Array maintenance and service guide (257547-003, October 2006)

Message Type
Description Action
52 REDUNDANCY
FAILED PCI BUS
ERROR
Error
While either attempting
to enter redundant mode
or already operating in
redundant mode, one
of the array controllers
encountered a PCI bus
error on the communication
channel used between
the two array controllers.
Redundancy is disabled at
this time.
If the MSA is currently
involved in host I/O, remove
the standby array controller,
wait 10 seconds, and then
reinsert it, ensuring that it is
fully seated in the chassis.
If this does not resolve the
issue, wait until downtime
is available. Power off the
MSA, remove both array
controllers, and reinsert
them, ensuring they are fully
seated in the chassis.
Should the issue persist,
contact HP support.
53 REDUNDANCY
FAILED NO SECOND
CONTROLLER
Error
While operating in
redundant mode, one
of the array controllers was
removed. Redundancy is
disabled at this time.
Reinsert the missing array
controllerensuringthatitis
fully sea
ted in the chassis.
54 REDUNDANCY
FAILED CACHE DIMMS
MISMATCH
Error
The cache memory modules
on the two controllers are
not the same size. All
cache memory modules
must be the same size for
redundancy to operate.
Remove the array controller
that has been halted, replace
the cache modules with the
appropriately sized ones,
wait 10 seconds, and then
reinsert the array controller,
ensuring that it is fully seated
in the chassis.
55 MSA1000 ACTIVE
CONTROLLER
Informational
In dual-controller
active/passive
congurations, this
message is displayed
ontheactivecontrollerand
56 MSA1000 STANDBY
CONTROLLER is displayed
on the standby controller.
In dual-controller active/
active congurations, this
message is displayed on
both controllers.
56
MSA1000 STANDBY
C
ONTROLLER
Informational
I
n dual-controller
a
ctive/passive
c
ongurations, this
m
essage is displayed on
the standby controller and
55 MSA1000 ACTIVE
CONTROLLER is displayed
ontheactivecontroller.
57 REMOVE OTHER
CONTROLLER NOW
Error
In dual-controller
congurations, the rmware
has determined that the
other controller has been
disabled and can safely be
removed.
Remove the other array
controller for the planned
service. When complete,
reinsert the array controller,
ensuring that it is fully seated
in the chassis.
42
LCD panel and message descriptions