HP StorageWorks HSG80 ACS Solution Software V8.8 for Linux X86 Installation and Configuration Guide (AA-RV1LA-TE, March 2005)

FC Configuration Procedures
123HSG80 ACS Solution Software V8.8 for Linux X86 Installation and Configuration Guide
Cabling a Single Controller
The cabling for a single controller is shown in Figure 36.
Note: It is a good idea to plug only the controller cables into the switch. The host
cables are plugged into the switch as part of the configuration procedure ("Configuring
a Single Controller Using CLI", page 123).
Figure 36: Single controller cabling
Configuring a Single Controller Using CLI
To configure a single controller using CLI involves the following processes:
"Verifying the Node ID and Check for Any Previous Connections", page 124
"Configuring Controller Settings", page 125
"Restarting the Controller", page 125
"Setting Time and Verifying All Commands", page 125
"Plugging in the FC Cable and Verifying Connections", page 128
"Repeating Procedure for Each Host Adapter", page 128
1 Controller
2 Host port 1
3 Host port 2
4 Cable from the switch to the host Fibre Channel
adapter
5 FC switch
CXO6881B
1
5
5
3
2
4
4