HP StorageWorks HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide (AA-RV1HA-TE, March 2005)

FC Configuration Procedures
140 HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide
21. Set the SCSI version by entering the following command:
HSG> SET THIS_CONTROLLER SCSI VERSION= <SCSI-2 or SCSI-3>
22. Determine if the operating system set for the online controller connection is
AIX_CAMBEX, by entering the following command:
HSG> SHOW CONNECTIONS
Although an IBM operating system entry exists in the CLI and SWCC for the
fibre channel connection, use default setting AIX_CAMBEX for operation
with your IBM host. The IBM setting may cause problems when LUNs are
not available to AIX or during controller failover. If so, use:
HSG> SET !NEWCONxx OPERATING_SYSTEM=AIX_CAMBEX
where: xx is the online connection ID produced in the SHOW CONNECTIONS
command above.
Note: Further information on command syntax can be found in the
HP StorageWorks
HSG60 and HSG80 Array Controller and Array Controller Software Command Line
Interface Reference Guide
.
23. Restart the controllers for the new settings to take effect, by entering the
following command:
HSG> RESTART OTHER_CONTROLLER
HSG> RESTART THIS_CONTROLLER
It takes about one minute for the CLI prompt to come back after a RESTART
command.
Setting Time and Verifying All Commands
1. Set the time on the controller by entering the following syntax:
SET THIS TIME=DD-MMM-YYYY:HH:MM:SS
2. Use the FRUTIL utility to set up the battery discharge timer. Enter the
following command to start FRUTIL:
HSG > RUN FRUTIL
When FRUTIL asks if you intend to replace the battery, answer Y:
Do you intend to replace this controller's cache battery? Y/N
[N] Y