HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide (EK-G80TS-SA. C01, March 2005)

Last Failure Codes
262 HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide
43170100 Call to VA$ENABLE_NOTIFICATION( ) failed due to insufficient
resources.
01
43190100 Unable to allocate necessary memory in HPP_INIT( ).01
431A0100 Unable to allocate necessary timer memory in HPP_INIT( ).01
43210101 HPP detected unknown error indicated by HPT.
Last failure parameter [0] contains the error value.
01
43220100 Unable to obtain free CSR in HPP( ).01
43230101 During processing to maintain consistency of the data for persistent
reserve SCSI commands, an internal inconsistency was detected.
Last failure parameter [0] contains a code defining the precise nature of
the inconsistency.
01
44640100 Not enough abort requests in the system. 01
44650100 Exceeded the number of SCSI Exchange State Table (SEST) abort retries. 01
44660100
44670100
44680100
44690100
446A0100
446B0100
446C0100
446D0100
446E0100
446F0100
Unable to allocate enough abort requests for Fibre Channel host port
transport software layer.
Changes to command HTBs.
Changes to FC HTBs.
Changes to work requests.
Changes to HTBs.
Changes to TIS structures.
Changes to MFSs.
Changes to TACHYON headers.
Changes to EDB structures.
Changes to LSFS structures.
01
44700100 Unable to allocate enough TPS structures for Fibre Channel host port
transport software layer.
01
44720101 An illegal status was returned to the Fabric Login (FLOGI) command
error handler:
Last failure parameter [0] contains error value.
01
Table 56: Last Failure Codes and Repair Action Codes (Sheet 49 of 55)
Last
Failure
Code
Description
Repair
Action
Code