Last Failure Codes
260 HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide
200E0101 While traversing the structure of a unit, a CONFIG_INFO node was
discovered with an unrecognized structure type:
Last failure parameter [0] contains the structure type number that was
unrecognized.
01
200F0101 A CONFIG_INFO node was discovered with an unrecognized structure
type:
Last failure parameter [0] contains the structure type number that was
unrecognized.
01
20100101 A CONFIG_INFO of type VA_MA_DEVICE had an unrecognized SCSI
device type:
Last failure parameter [0] contains the SCSI device type number that was
unrecognized.
01
20110100 An attempt to allocate memory so that the CLI prompt messages could be
deleted failed.
01
20120101 While traversing the structure of a unit, a CONFIG_INFO node was
discovered with an unrecognized structure type:
Last failure parameter [0] contains the structure type number that was
unrecognized.
01
20130101 While traversing the structure of a unit, the device was of an
unrecognized type:
Last failure parameter [0] contains the SCSI device type that was
unrecognized.
01
20160000 In order to go into Mirrored Cache mode, the controllers must be
restarted.
00
20160100 Unable to allocate resources needed for the CLI local program. 01
20170000 In order to go into Nonmirrored Cache mode, the controllers must be
restarted.
00
20190010 A cache state of a unit remains WRITE_CACHE_UNWRITTEN_DATA.
The unit is not online; thus this state would be valid only for a very short
period of time.
00
201A0100 An attempt to allocate memory so that a CLI prompt message could be
reformatted failed.
01
Table 56: Last Failure Codes and Repair Action Codes (Sheet 47 of 55)
Last
Failure
Code
Description
Repair
Action
Code