HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide (EK-G80TS-SA. C01, March 2005)

ASC, ASCQ, Repair Action, and Component Identifier Codes
166 HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide
D1 09 Unexpected tag message.
D1 0A Channel busy.
D1 0B Device initialization failure. Device sense data available.
D2 00 Miscellaneous SCSI driver error.
D2 03 Device services had to reset the bus.
D3 00 Drive SCSI chip reported gross error.
D4 00 Non-SCSI bus parity error.
D5 02 Message reject received on a valid message.
D7 00 Source driver programming error.
E0 03 Fault Manager detected an unknown error code.
E0 06 Maximum number of errors for this I/O exceeded.
E0 07 Drive reported recovered error without transferring all
data.
Table 48: ASC and ASCQ Code Descriptions (Sheet 5 of 5)
ASC
Code
ASCQ
Code
Description