HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide (EK-G80TS-SA. C01, March 2005)

ASC, ASCQ, Repair Action, and Component Identifier Codes
165HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide
A1 00 Shelf OK is not properly asserted.
A1 01 Unable to clear swap interrupt. Interrupt disabled.
A1 02 Swap interrupt re-enabled.
A1 03 Asynchronous swap detected.
A1 04 Controller shelf OK is not properly asserted.
A1 0A EMU fault: power supplies not OK.
A1 0B EMU fault: fans not OK.
A1 0C EMU fault: temperature not OK.
A1 0D EMU fault: external air sense not OK.
A1 10 Power supply fault is now fixed.
A1 11 Fans fault is now fixed.
A1 12 Temperature fault is now fixed.
A1 13 External air sense fault is now fixed.
A1 14 EMU and cabinet now available.
A1 15 EMU and cabinet now unavailable.
A2 00 Peer-to-peer remote copy connection event.
A2 01 Remote copy set membership event.
B0 00 Command timeout.
B0 01 Watchdog timer timeout.
D0 01 Disconnect timeout.
D0 02 Chip command timeout.
D0 03 Byte transfer timeout.
D1 00 Bus errors.
D1 02 Unexpected bus phase.
D1 03 Disconnect expected.
D1 04 ID message not sent.
D1 05 Synchronous negotiation error.
D1 07 Unexpected disconnect.
D1 08 Unexpected message.