Compaq StorageWorks HSG60 ACS Solution V8.6 for SGI IRIX Installation and Configuration Guide

Planning Storage 219
Plan the mirrorset members, then plan the stripeset that will contain them. Review the
recommendations in Storageset Planning Considerations, page 210, and Mirrorset
Planning Considerations, page 213.
Storageset Expansion Considerations
Storageset Expansion allows for the joining of two of the same kind of storage
containers by concatenating RAIDsets, Stripesets, or individual disks, thereby forming
a larger virtual disk which is presented as a single unit. The Compaq StorageWorks
HSG60 Array Controller (ACS) Version 8.6 CLI Reference Guide describes the CLI
command: ADD CONCATSETS which is used to perform concatenation.
CAUTION: The ADD CONCATSETS command should only be executed with
host operating systems that support dynamic volume expansion. If the operating
system cannot handle one of its disks increasing in size, use of this command could
make data inaccessible.
Partition Planning Considerations
Use partitions to divide a container (storageset or individual disk drive) into smaller
pieces, each of which can be presented to the host as its own storage unit. Figure 214
shows the conceptual effects of partitioning a single-disk container.
Figure 214. One example of a partitioned single-disk unit
1 Partition 1
2 Partition 2
3 Partition 3
1
2
3
CXO7056A