Compaq StorageWorks HSG60 ACS Solution V8.6 for SGI IRIX Installation and Configuration Guide

210 HSG60 ACS Solution Software Version 8.6 for SGI Irix Installation and Configuration Guide
Storageset Planning Considerations
This section contains the guidelines for choosing the storageset type that would best
work in your subsystem:
Stripeset Planning Considerations on page 210
Mirrorset Planning Considerations on page 213
RAIDset Planning Considerations on page 215
Striped Mirrorset Planning Considerations on page 217
Storageset Expansion Considerations on page 219
Partition Planning Considerations on page 219
NOTE: Storageset expansion is synonymous with Concat Set.
Stripeset Planning Considerations
Stripesets (RAID 0) enhance I/O performance by spreading the data across multiple
disk drives. Each I/O request is broken into small segments called chunks. These
chunks are then simultaneously striped across the disk drives in the storageset,
thereby enabling several disk drives to participate in one I/O request.
For example, in a three-member stripeset that contains disk drives Disk10000,
Disk20000, and Disk10100, the first chunk of an I/O request is written to Disk10000,
the second to Disk 20000, the third to Disk 10100, the fourth to Disk10000, and so
forth until all of the data has been written to the drives (Figure 27).