Compaq StorageWorks HSG60 ACS Solution V8.6 for SGI IRIX Installation and Configuration Guide

Planning a Subsystem 121
If the HSG60 controller parameter settings displayed do not match those in the
Recommended Settings column in Table 13, the following CLI commands can be used to
alter their values.
NOTE: HSG60> is included in the CLI commands to show the prompt that will appear and is not
to be typed as part of the command line.
Setting the Port Topology:
HSG60 >SET OTHER_CONTROLLER PORT_1_TOPOLOGY=FABRIC
HSG60 >SET OTHER_CONTROLLER PORT_2_TOPOLOGY=FABRIC
Setting the SCSI Version:
HSG60 >SET THIS_CONTROLLER SCSI_VERSION=SCSI-2
HSG60 >SET THIS_CONTROLLER SCSI_VERSION=SCSI-2
If the StorageWorks Command Console (SWCC) will be used, the HSG60 Command
Console LUN must be enabled.
HSG60>SET THIS_CONTROLLER COMMAND_CONSOLE_LUN
Once all of the changes have been made, restart both controllers as follows:
HSG60>RESTART OTHER_CONTROLLER
HSG60>RESTART THIS_CONTROLLER
Once both controllers have been restarted, the connection type must be set. First examine
the connections by typing:
HSG60>SHOW CONNECTIONS
In the following command substitute the [CONNECTIONNAME] with the names shown
in the output of the
SHOW CONNECTIONS command.
Table 13 Controller Parameters and Recommended Settings for Fabric
Controller Parameter Recommended Setting
PORT_1_Topology Fabric
PORT_2_Topology Fabric
This_Controller SCSI_Version SCSI-2
Other_Controller SCSI_Version SCSI-2