Compaq StorageWorks HSG60 ACS Solution Software V8.6 for Sun Solaris Installation and Configuration Guide

Configuration Procedures 5–3
Establishing Connection with a SPARC System
To set up your SPARC system for connection with the HSG60 Controller, follow these
steps:
1. Use the supplied serial cable and the 9 to 25 pin RS-232 adapter (P/N=12-45238-01) to
connect the serial port on the SPARC system to the serial port on the RAID array
controller.
2. If you use a SUN A/B Serial Splitter Cable, and/or you attach the controller to serial
port A, you may need to modify the remote file to specify ttya as follows:
a. Open the file /ETC/REMOTE with an editor.
b. Locate the lines:
hardwire:\
:dv:/dev/ttyb:br#9600…
c. Change ttyb to ttya
d. Save the file.
3. Open a terminal window from the Desktop Program menu.
4. Start the Terminal Interface Program (TIP), at the prompt type:
tip hardwire
Press Enter.
5. Press Enter again, and a CLI prompt (similar to the following) appears in the window:
HSG60>
Setting Up a Single Controller
Power Up and Establish Communication
1. Connect the computer or terminal to the controller as shown in Figure 51. The
connection to the computer is through the COM1 or COM2 ports.
2. Turn on the computer or terminal.
3. Apply power to the storage subsystem.
4. Configure the computer or terminal as follows:
9600 baud
8 data bits