Compaq StorageWorks HSG60 ACS Solution Software V8.6 for Linux X86 and Alpha Installation and Configuration Guide

5–22 HSG60 ACS Solution Software Version 8.6 for Linux X86 and Alpha Installation and Configuration Guide
Adding Disk Drives
If you add new disk drives to the subsystem, the disk drives must be added to the
controllers list of known devices:
To add one new disk drive to the list of known devices, enter the following command:
ADD DISK DISKNNNNN P T L
To add several new disk drives to the list of known devices, enter the following
command:
RUN CONFIG
Adding a Disk Drive to the Spareset
The spareset is a collection of spare disk drives that are available to the controller should it
need to replace a failed member of a RAIDset or mirrorset.
NOTE: This procedure assumes that the disks that you are adding to the spareset have already
been added to the controller's list of known devices.
To add the disk drive to the controller's spareset list:
ADD SPARESET DISKNNNNN
Repeat this step for each disk drive you want to add to the spareset:
For example:
The following example shows the commands for adding DISK11300 and DISK21300 to
the spareset.
ADD SPARESET DISK11300
ADD SPARESET DISK21300
Removing a Disk Drive from the Spareset
You can delete disks in the spareset if you need to use them elsewhere in your subsystem.
NOTE: The RUN CONFIG command does not delete disks from the controllers’ device table if a
disk has been physically removed or replaced. In this case, use the command DELETE
DISKNNNNN.
1. Show the contents of the spareset using the following command:
SHOW SPARESET