MIB Reference Manual (Version 3.0)

1-8 MIB Reference Manual Version 3.0
MIB-II Object Types
1
sysUpTime
Syntax TimeTicks
Access Read-only
Status Mandatory
Description The time (in hundredths of a second) since the network management portion of the system was last
re-initialized.
sysContact
Syntax Display String of size 0 to 255
Access Read-write
Status Mandatory
Description The textual identification of the contact person for this managed node, together with information on
how to contact this person.
Note: Default value = Field Support.
This value can be set using the agtcfgSet telnet command.
sysName
Syntax Display String of size 0 to 255
Access Read-write
Status Mandatory
Description An administratively-assigned name for this managed node. By convention, this is the node’s
fully-qualified domain name.
Note: Default value = pre-assigned name of the switch.
sysLocation
Syntax Display String of size 0 to 255
Access Read-write
Status Mandatory
Description The physical location of this node, (for example, telephone closet, 3rd floor).
Note: Default value = End User Premise.
This value can be set using the agtcfgSet telnet command.