HP Surestore FC 1Gb/2Gb Switch 8B Installation and Reference Guide

Installation and Reference Guide 2-21
Installing and Configuring the Switch
2
Setting Up Speed Negotiation
There are two methods for configuring the ports on the FC Entry Switch 8B and FC Switch 8B. The
port can be set to auto-sensing mode, which allows the port to automatically be configured to the
highest speed. Ports can also be set to a fixed speed of either 1 or 2 Gbps.
To display the configuration settings of the ports on a switch, use the portCfgShow. The port
speed is displayed as 1G (fixed speed of 1 Gbps), 2G (fixed speed of 2 Gbps), or AN
(auto-negotiate). To set the speed level for all the ports on a switch, use the telnet command
switchCfgSpeed. To set the speed level for a single port, use the portCfgSpeed.
Depending on your environment you may need to force a port to use a specific speed level. Auto
negotiation may not be supported by the device. Check the configuration information for your
network components for specific requirements. See the Fabric OS Reference Manual for a detailed
command description.
Configuring Supported Devices
HP Surestore Director FC-64 Switch
The FC Entry Switch 8B or FC Switch 8B switch can be used with the HP Surestore Director
FC-64 switch. Specific configurations must be set on both devices to make this work.
On the FC Entry Switch 8B or FC Switch 8B, log on to the switch with administrative privileges
and enter the following telnet commands:
1. switchDisable
2. interopMode 1
3. switchEnable
On the Director FC-64 switch, the following steps must be completed to configure the switch for
interoperability:
Step 1: Verify Unique Domain IDs
Step 2: Select a Single Surestore FC-64 Director as Principal Switch
Step 3: Verify Unique Zone Names
Step 4: Verify Brocade Product Zoning Configurations
Step 5: Verify Zone Naming Conventions
Step 6: Verify Operating Mode
Step 7: Verify Surestore FC-64 Director Switches’ Operating Parameters
Step 8: Verify Firmware Version
Step 9: Verify EFC Manager Version
Step 10: Verify Private Loop Targets on Brocade Products are Translated to Fabric
Step 11: Add Switches to Fabric
Step 12: Complete Zoning Activities
Step 13: Save Active Zone Set
For complete instructions on configuring the HP Director FC-64 switch see “Checklist for Merging
Fabrics” in the Merging Heterogeneous Fabrics Instructions white paper on the FC Entry Switch
8B and FC Switch 8B Documentation CD.