Fibre O ptic Fibr
e Channel cables
The Enterprise Virtual Array uses orange, 50-m, multi-mode, ber optic cables for connection to the
SAN. The ber optic cable assembly consists of t wo, 2–m ber optic strands and small form-factor
connectors on e
ach end. See Figure 13.
To ensure optim
um operation, the ber optic cable components require protection from co ntamination
and mechanical hazards. Failure to p rovide this protection can cause degraded operation. Observe the
following precautions when using ber optic cables.
To avoid breaking the ber within the cable:
•Donotkinkth
e cable
Do not use a cable bend-radius of less than 30 mm (1.18 in)
To avoid deforming, or possibly breaking the ber within the cable, do not place heavy objects
on the cable
.
To avoid contaminating the op tical connectors:
Do not touch the connectors
•Neverleave
the connectors exposed to the a ir
Install a dust cover on each transceiver and ber cable connector when they are disconnected
If an open connector is exposed to dust, or there is any doubt about the cleanliness of the connector,
clean the c
onnector as described in Handling ber optic cables.
CXO7972
A
Figure 13 Fibre Optic Fibre Channel cable
Copper Fibre Channel cables
The Enterprise Virtual Array Fibre Channel 10000-Series implementation uses copper Fibre Channel
cables to connect the drive enclosures to each other, or to the loop switches and to the HSV controllers.
The cabl
es are available in 0.6–meter and 2.0–meter leng ths. Copper cables provide performance
compara
ble to ber optic cables. Copper cable connectors differ from ber optic sma ll form-factor
connectors (see Figure 14).
8164A-ST
Figure 14 Copper Fibre Channel cable
Fibre Channel disk drives
The Fibre Channel disk drives are hot-pluggable and include the following features:
Dual-ported 2–Gbps Fibre Channel drive enclosure interface that allows up to 120 disk drives to
be supported p er Fibre Channel drive enclosure pair.
Compact, direct-connect design for maximum storage density and increased reliability and
signal integrity.
Both o n line high-performance disk drives and FATA d isk drives in a variety of capacities and
spindle speeds.
Better vibration damping for improved per formance.
Enterprise Virtual Array 3000/5000 user guide
47