HP StorageWorks HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide (AA-RV1FA-TE, March 2005)
FC Configuration Procedures
164 HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide
When FRUTIL asks if you intend to replace the battery, answer Y:
Do you intend to replace this controller's cache battery? Y/N
[N] Y
FRUTIL prints out a procedure, but does not give you a prompt. Ignore the
procedure and press Enter.
12. Set up any additional optional controller settings, such as changing the CLI
prompt. See the
SET THIS CONTROLLER/OTHER CONTROLLER command in the HP
StorageWorks HSG60 and HSG80 Array Controller and Array Controller
Software Command Line Interface Reference Guide for the format of optional
settings. Perform this step on both controllers.
13. Verify that all commands have taken effect by entering the following
command:
SHOW THIS