HP StorageWorks HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide (AA-RV1FA-TE, March 2005)

FC Configuration Procedures
152 HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide
Establishing a Local Connection
A local connection is required to configure the controller until a command console
LUN (CCL) is established using the CLI. Communication with the controller can
be through the CLI or SWCC.
The maintenance port, shown in Figure 40, provides a way to connect a
maintenance port. The maintenance port can be an EIA-423 compatible terminal
or a computer running a terminal emulator program. The maintenance port
accepts a standard RS-232 jack. The maintenance port cable shown in Figure 40
has a 9-pin connector molded onto the end for a PC connection. If you need a
terminal connection or a 25-pin connection, you can order optional cabling.
Figure 40: Maintenance port connection
Caution: The maintenance port generates, uses, and can radiate
radio-frequency energy through its cables. This energy may interfere with
radio and television reception. Disconnect all maintenance port cables when
not communicating with the controller through the local connection.
1 Maintenance Port
Cable
2 Maintenance Port
1 2 3 4 5 6
1
2