HP StorageWorks HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide (AA-RV1FA-TE, March 2005)
Preparing the Host System
121HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide
Note: Rolling upgrades are not supported on HP-UX when configured with Secure
Path.
Preparing Storage RAID Array
Prepare the Enterprise/Modular Storage RAID Array by following these
recommended steps:
1. Verify the storage system is operating properly.
a. Check that the date and time are set properly by typing:
HSG80> show this
b. Check that no units are in a failed state by typing:
HSG80> show storage
c. Verify the cache battery is fully charged by typing:
HSG80> show this
2. Check the disks and disable writeback cache on all unit by typing the
following commands. Make a note of all units changed.
HSG80> show d1
HSG80> set d1 nowriteback_cache
3. Disable mirrored cache by typing:
HSG80> set this nomirrored_cache
Preparing HP-UX System
Recommendations for preparing the HP-UX system prior to upgrading your ACS
firmware are:
1. Build and verify a full backup of your HP-UX system as close as possible to
the time you intend to upgrade your ACS firmware.
2. Make a backup copy of your HP-UX kernel for safety recovery.
3. Build a mapping of your volume groups. Export them into map files.
4. Save a listing of all mounted file systems.
5. Shut-down all SWCC Agents. For MC/ServiceGuard clusters this must be
done on all nodes.