contents of this section
features
specifications
physical specification
power requirements
performance
operating limits
non-operating limits
safety and electromagnetic compatibility
features
The HP Surestore DLT VS80 tape drive provides affordable 80GB backup to IT
managers with mid-range servers. The 6MB/s compressed transfer rate provides
backup in under 4 hours. DLT technology appeals to customers looking for
reliable and scalable backup.
Your new tape drive provides the following key features:
● Proven DLT technology
● Up to 80GB (compressed) on a single tape cartridge
● Transfer rate of 6MB/s (compressed)
● Read compatible with DLT4000 data
● Technology scalable to higher capacities and transfer rates
● Compatibility with all key backup software applications
● TapeSense System™ to improve reliability by rejecting damaged media
● Roller design to minimize lateral tape movement
● TapeAlert support for worry-free backup
● HP Library & Tape Tools software to verify successful installation and
troubleshoot problems
● HP Instant Support for web-based problem identification, diagnosis and
resolution providing fast, easy-to-use online solutions to problems.
● Ultra wide SCSI-2 interface
● 3-year, next-day, unit exchange
specifications
physical specification
dimensions
212.1 mm (8.35") W
66.2 mm (2.61") H
272.5 mm (10.73") D
weight 3.5 kg (7.72 lbs)
power requirements
power
100-254 VAC
50/60 Hz 0.9A
Auto-ranging. Power connection IEC
CEE-22
performance
interface Ultra wide SCSI-2
recording format DLT1
media DLTtape IV
capacity 40 GB (native)
transfer rate
native 3 MB/sec
compressed 6 MB/sec (assumes 2:1
compression)
burst transfer rate 20 MB/sec (Ultra wide SCSI-2)
file access time (from BOT)
68 sec typical
135 sec maximum
load to BOT 59sec (slightly longer for blank tapes)
unload from BOT 17 sec
rewind time
68 sec typical
135 sec maximum
rewind tape speed 4.1 m/sec (160 in/sec)
operating limits
temperature 10°C to 40°C (50°F to 104°F)
humidity
20% to 80% RH (non-condensing)
10%/hr maximum operating humidity
rise
maximum wet bulb temperature 25°C
temperature gradient 11°C per hour (across range)
operating altitude -0.15 to 9 km (-500 to 30,000 ft)
vibration 0.25g 5-500 Hz
shock survival 10g 10ms (half sine)
non-operating limits (storage ranges)
temperature -40°C to 66°C (-40°F to 151°F)
humidity 10% to 95% RH (non-condensing)
temperature rise
20°C per hour with 5 degree margin
(across range)
humidity rise 10%/hr
non-operating altitude N/A
vibration 1g 10-500 Hz
shock survival
40G 10ms (square wave)
140G 2ms (half sine)
safety and electromagnetic compatibility
UL 1950, 3rd edition Information Technology Equipment (ITE)
CSA-C22.2 No. 950-95 Safety of Information Technology Equipment
FCC Rules and Regulations, Part 15--Radio Frequency Devices,
Subpart B--Unintentional Radiators, Class B
Industry Canada (ICES), Radio Interference Regulation, Digital
Apparatus, Class B
C-TICK, AS/NZS A53548, Radio Frequency Devices Class B
CISPR Publication 22 (1985), Class B
EN55022: 1998, CISPR Publication 22 (1997), CISPR Publication 22
(1993) (U.S.A.), Radiated and Conducted Emissions
EN61000-3-2: 1995, +Amendment A1: 1998, +Amendment A2: 1998,
IEC 61000-3-2: 1995, +/A1: 1997, +/A2: 1998, Harmonic Current
Emissions
EN61000-3-3: 1995, IEC61000-3-3: 1994, Voltage Fluctuation and
Flicker
EN55024: 1998, CISPR Publication 24 (1997), IEC61000-4-2: 1995,
IEC61000-4-3: 1995, IEC61000-4-5: 1995, IEC61000-4-6: 1996,
IEC61000-4-8: 1993, IEC61000-4-11: 1994, Immunities
CE-Mark comprised of the following requirements:
EN60950/A11: 1997, IEC60950/A4: 1996, Safety of Information
Technology Equipment including Electrical Business Equipment
EN55082-1/IEC1000-4-2, 1000-4-3, 1000-4-4, Electromagnetic
Compatibility for Industrial-Process Measurement and Control
Equipment:
Part 2 - Electrostatic Discharge (ESD) Requirements
Part 3 - Radiated Electromagnetic Field Requirements
Part 4 - Electrical Fast Transient/Burst (EFT) Requirements
© 2001, Hewlett-Packard Company