HP StorageWorks HSG80 ACS Solution Software V8.8 for OpenVMS Installation and Configuration Guide (AA-RV1PA-TE, March 2005)

Planning a Subsystem
37HSG80 ACS Solution Software V8.8 for OpenVMS Installation and Configuration Guide
The unit would not be visible at all to a host connection with a unit offset of 18 or
greater, because that offset is not within the units range (unit number of 17 minus
offset of 18 is a negative number).
In addition, the access path to the host connection must be enabled for the
connection to access the unit. This is done through the ENABLE_ACCESS_PATH
switch of the ADD UNIT (or SET unit) command.
The PREFERRED_PATH switch of the
ADD UNIT (or SET unit) command
determines which controller of a dual-redundant pair initially accesses the unit.
Initially, PREFERRED_PATH determines which controller presents the unit as
Ready. The other controller presents the unit as Not Ready. Hosts can issue a SCSI
Start Unit command to move the unit from one controller to the other.
Assigning Unit Numbers Depending on SCSI_VERSION
The SCSI_VERSION switch of the SET
THIS_CONTROLLER/OTHER_CONTROLLER command determines how the
CCL is presented. There are two choices: SCSI-2 and SCSI-3. The choice for
SCSI_VERSION affects how certain unit numbers and certain host connection
offsets interact.
Note: OpenVMS requires the controllers be set to SCSI-3 mode.
Assigning Host Connection Offsets and Unit Numbers in SCSI-3 Mode
If SCSI_VERSION is set to SCSI-3, the CCL is presented as LUN 0 to all
connections. The CCL supersedes any other unit assignment. Therefore, in
SCSI-3 mode, a unit that would normally be presented to a connection as LUN 0
is not visible to that connection at all.
The following methods are recommended for assigning host connection offsets
and unit numbers in SCSI-3 mode:
Offsets should be divisible by 10 (for consistency and simplicity).
Unit numbers should not be assigned at connection offsets (to avoid being
masked by the CCL at LUN 0).
For example, if a host connection has an offset of 20 and SCSI-3 mode is selected,
the connection will see LUNs as follows:
LUN 0 - CCL
LUN 1 - unit 21