316 Troubleshooting
ISL R_RDY Mode .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..
RSCN Suppressed .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..
Persistent Disable.. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..
NPIV capability ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON
where AN:AutoNegotiate, ..:OFF, ??:INVALID,
SN:Software controlled AutoNegotiation.
4. Enter the portErrShow command; then, check for errors that can cause login problems:
switch:admin> porterrshow
frames enc crc too too bad enc disc link loss loss frjt fbsy
tx rx in err shrt long eof out c3 fail sync sig
=====================================================================
0: 12m 0 0 0 0 0 0 3.8g 0 3 0 0 0 0
1: 17 18 0 0 0 0 0 1.4k 0 2 0 0 0 0
2: 0 0 0 0 0 0 0 0 0 2 0 0 0 0
3: 0 0 0 0 0 0 0 0 0 2 0 0 0 0
4: 0 0 0 0 0 0 0 0 0 3 0 0 0 0
5: 0 0 0 0 0 0 0 0 0 2 0 0 0 0
6: 0 0 0 0 0 0 0 0 0 2 0 0 0 0
7: 0 0 0 0 0 0 0 0 0 2 0 0 0 0
8: 0 0 0 0 0 0 0 0 0 3 0 0 0 0
9: 0 0 0 0 0 0 0 0 0 2 0 0 0 0
10: 0 0 0 0 0 0 0 0 0 2 0 0 0 0
11: 0 0 0 0 0 0 0 0 0 2 0 0 0 0
12: 0 0 0 0 0 0 0 0 0 3 0 0 0 0
13: 0 0 0 0 0 0 0 0 0 2 0 0 0 0
14: 17 18 0 0 0 0 0 222k 0 2 0 0 0 0
15: 6 22 0 0 0 0 0 15 0 2 0 0 0 0
• A high number of errors relative to the frames transmitted and frames received can indicate a
marginal link (see ”Correcting marginal links” on page 321 for additional information).
• A steadily increasing number of errors can indicate a problem. Track errors by sampling the port
errors every five or ten minutes.
5. Enter the portFlagsShow command; then, check to see how a port has logged in and where a login
failed (if a failure occurred):
switch:admin> portflagsshow
Port SNMP Physical Flags
-------------------------------
0 Offline In_Sync PRESENT U_PORT LED
1 Online In_Sync PRESENT ACTIVE F_PORT G_PORT U_PORT
LOGICAL_ONLINE LOGIN NOELP LED ACCEPT
2 Offline No_Light PRESENT U_PORT LED
3 Offline No_Module PRESENT U_PORT LED
4 Offline No_Module PRESENT U_PORT LED
5 Offline No_Light PRESENT U_PORT LED
6 Offline No_Module PRESENT U_PORT LED
7 Offline No_Module PRESENT U_PORT LED