HP StorageWorks Fabric OS 6.1.x administrator guide (5697-0234, November 2009)

Fabric OS 6.1.x administrator guide 371
switch:admin> porttrunkarea --show enabled
Slot Port Type State Master TI DI
-------------------------------------------
10 13 -- -- -- 125 125
10 14 -- -- -- 125 126
-------------------------------------------
5. Enable ports 13 aD 14:
switch:admin> portenable 10/13
switch:admin> portenable 10/14
6. Show the TA port configuration after enabling the ports:
switch:admin> porttrunkarea --show enabled
Slot Port Type State Master TI DI
-------------------------------------------
10 13 F-port Master 10/13 125 125
10 14 F-port Slave 10/13 125 126
Enabling F_Port trunking
The following example shows how to enable F_Port trunking on a stand-alone switch using ports 36-39.
1. Disable ports 36 - 39 by executing portDisable port for each port to be included in the TA.
2. Enable Trunk Area for ports 36 - 39 with area number 37:
switch:admin> porttrunkarea --enable 36-39 -area 37
Trunk area 37 enabled for ports 36, 37, 38 and 39.
3. Re-enable ports 36-39 by issuing portEnable port for each port in the TA.
4. Show switch/port information:
switch:admin> switchshow
switchName: SPIRIT_B4_01
switchType: 66.1
switchState: Online
switchMode: Native
switchRole: Principal
switchDomain: 2
switchId: fffc02
switchWwn: 10:00:00:05:1e:41:22:80
zoning: OFF
switchBeacon: OFF
FC Router: ON
FC Router BB Fabric ID: 100
Area Port Media Speed State Proto
=====================================
0 0 -- N8 No_Module
1 1 -- N8 No_Module
2 2 -- N8 No_Module
3 3 -- N8 No_Module
4 4 -- N8 No_Module
5 5 -- N8 No_Module
6 6 -- N8 No_Module
7 7 -- N8 No_Module
8 8 id N4 Online F-Port 10:00:00:00:00:01:00:00
9 9 -- N8 No_Module
10 10 -- N8 No_Module
11 11 -- N8 No_Module
12 12 -- N8 No_Module
13 13 -- N8 No_Module
14 14 -- N8 No_Module
15 15 -- N8 No_Module
16 16 -- N8 No_Module
17 17 -- N8 No_Module
18 18 -- N8 No_Module
19 19 -- N8 No_Module