Table 11 Fabric OS 6.2.2 closed defects (continued)
SolutionClosed defect summary
Fixed in Fabric OS 6.2.2Fabric Watch SFP messages get logged after upgrade to Fabric OS 6.1.1b,
due to I2C read values of 0xff and I2C NACK error case not being properly
handled.
Fixed in Fabric OS 6.2.2Switch gets nsd panic when third-party switch in interopmode 3 and Fabric
OS 6.2 sends invalid frames.
Fixed in Fabric OS 6.2.2Server does not see some devices on shared primary ports connected to
48 port blades using domain/port session based zoning.
Fixed in Fabric OS 6.2.2The configdownload command does not load tstimezone info after
changing tzh and tzm in the config.txt file to new values.
Workaround prior to update: Set up
tstimezone through CLI.
Fixed in Fabric OS 6.2.2Transient detected error on internal link caused 8-Gb blade to be faulted
with reason=5 or 4.
Workaround prior to update: Use
slotpoweroff and slotpoweron to
clear the fault.
Fixed in Fabric OS 6.2.2When running the Zone admin, with 48 port blade where there is port
address sharing, devices show up on the wrong port. When port index and
port address of the given port is different, end device will be seen connected
to a different port (U port) than the original one (F_Port).
Fixed in Fabric OS 6.2.2HP StorageWorks DC Switch Encryption blade comes up faulty after
firmwaredownload -sf and reboot of both CPs at the same time.
Workaround prior to update: Reseat the
blade.
Fixed in Fabric OS 6.2.2After upgrade to Fabric OS 6.x, rsh using user credential gets
ifmodeshow eth0: ioctl (ETHTOOL_GSET) failed error in
Workaround prior to update: Set suid
permissions for ethmode: chmod +s
/fabos/libexec/ethmode
response to ifmodeshow command. Telnet and rsh with root credential
work fine.
Fixed in Fabric OS 6.2.2Backup job stopped for an extended period of time when running through
HP StorageWorks Encryption switch or encryption blade after bouncing 1
of the 2 connected ISLs.
Fixed in Fabric OS 6.2.2The 4Gb SAN Switch for HP c-Class BladeSystem AG may login to DC
SAN Director with wrong PWWN.
Workaround prior to update: Reboot AG.
Fixed in Fabric OS 6.2.2During director switch initialization from power on, reboot, or hafailover,
daemons fail to load causing switch to auto reboot and ffdc HAM-1008
and HAM-1007 errors are observed.
Fixed in Fabric OS 6.2.2When running a third-party host scan, the http daemon (weblinker.fcg)
terminates and restarts several times, causing a temporary management
service interruption.
Fixed in Fabric OS 6.2.2In Fabric OS 6.2, OID for connUnitType no longer returns the correct
access gateway mode status after upgrade from Fabric OS 6.1.1d to 6.2.0f.
Fixed in Fabric OS 6.2.2Fabric binding does not work in 239 domain mode in Interopmode 3 with
FCR on 8Gb switches. EX port rejects it.
Fixed in Fabric OS 6.2.2Fabric Watch sometimes logs messages with values above 100%. Most
likely occurs during first Fabric Watch polling cycle after slotstatsclear
command is issued.
Fixed in Fabric OS 6.2.2The following message may display on the console while firmware commit
is in progress: ssnGet: Unable to get WWN info.sw=0 rc=-5.
Fixed in Fabric OS 6.2.2While doing a disruptive CP reboot on a director class switch (reboot active
CP when no standby CP is present), if simultaneous fabric update causes
Fabric OS 6.2.2 fixes 43