Brocade Fabric OS Troubleshooting and Diagnostics Guide v6.2.0 (53-1001187-01, April 2009)

Fabric OS Troubleshooting and Diagnostics Guide 91
53-1001187-01
Troubleshooting FICON
11
Supportshow data is only valid if run within about 30 minutes of the failure in order for the data
to be valid.
Provide the IOCDS mainframe file.
This will define how all mainframe ports are configured.
Type of mainframe involved. Need make, model, and driver levels in use.
Type of actual Storage array installed. Many arrays will emulate a certain type of IBM array and
we need to know the exact make, model, and firmware of the array in use.
Read Brocade Release Notes for specific version of Fabric OS being installed.
The following sources provide useful problem-solving information:
The standard support commands (portLogDump, supportSave, supportShow) or the Fabric
Manager Event Log.
Other detailed information for protocol-specific problems:
- Display port data structures using the ptDataShow command.
- Display port registers using the ptRegShow command.
Identifying ports
The ficonShow rlir command displays, among other information, a tag field for the switch port. You
can use this tag to identify the port on which a FICON link incident occurred. The tag field is a
concatenation of the switch domain ID and port number, in hexadecimal format. The following
example shows a link incident for the switch port at domain ID 120, port 93 (785d in hex):
switch:admin> ficonshow rlir
{
{Fmt Type PID Port Incident Count TS Format Time Stamp
0x18 F 785d00 93 1 Time server Thu Apr 22 09:13:32 2004
Port Status: Link not operational
Link Failure Type: Loss of signal or synchronization
Registered Port WWN Registered Node WWN Flag Node Parameters
50:05:07:64:01:40:16:03 50:05:07:64:00:c1:69:ca 0x10 0x200115
Type number: 002064
Model number: 103
Manufacturer: IBM
Plant of Manufacture: 02
Sequence Number: 0000000169CA
tag: 155d
Switch Port WWN Switch Node WWN Flag Node Parameters
20:5d:00:60:69:80:45:7c 10:00:00:60:69:80:45:7c 0x00 0x200a5d
Type number: SLKWRM
Model number: 24K
Manufacturer: BRD
Plant of Manufacture: CA
Sequence Number: 000000000078
tag: 785d
}
}
The Local RLIR database has 1 entry.