Brocade Error Message Reference Guide v6.1.0 (53-1000600-02, June 2008)

Fabric OS Message Reference 197
53-1000600-02
FW-1048
30
Probable Cause Indicates that the value of the small form-factor pluggable (SFP) voltage has risen above the high
boundary. The supplied current of the SFP transceiver is outside of the normal range, indicating
possible hardware failure.
Recommended
Action
If the current rises above the high boundary, you must replace the SFP.
Severity WARNING
FW-1048
Message <timestamp>, [FW-1048], <sequence-number>,, INFO, <system-name>, <Label>, is
between high and low boundaries(High=<High value>, Low=<Low value>). Current value
is <Value> <Unit>.
Probable Cause Indicates that the value of the small form-factor pluggable (SFP) voltage has changed from a value
outside of the acceptable range to a value within the acceptable range.
Recommended
Action
No action is required. Respond to this message as is appropriate to the particular policy of the
end-user installation.
Severity INFO
FW-1049
Message <timestamp>, [FW-1049], <sequence-number>,, INFO, <system-name>, <Label>, value
has changed(High=<High value>, Low=<Low value>). Current value is <Value> <Unit>.
Probable Cause Indicates that the value of the small form-factor pluggable (SFP) voltage has changed. Frequent
voltage fluctuations are an indication that the SFP is deteriorating.
Recommended
Action
Replace the SFP if you see frequent voltage fluctuations.
Severity INFO
FW-1050
Message <timestamp>, [FW-1050], <sequence-number>,, WARNING, <system-name>, <Label>, is
below low boundary(High=<High value>, Low=<Low value>). Current value is <Value>
<Unit>.
Probable Cause Indicates that the value of the small form-factor pluggable (SFP) voltage has fallen below the low
boundary.
Recommended
Action
Configure the low threshold to 1 so that the threshold triggers an alarm when the value falls to 0
(Out_of_Range). If continuous or repeated alarms occur, replace the SFP before it deteriorates.
Severity WARNING