EM-1033
12
Recommended
Action
Close the ejector switch (raise the slider in most blades, or completely screw in the upper
thumbscrew for the FC4-48 port blade) if the field-replaceable unit (FRU) is intended for use. Refer
to the appropriate hardware manual for instructions on inserting the switch blades.
Severity ERROR
EM-1033
Message <timestamp>, [EM-1033], <sequence-number>,, ERROR, <system-name>, CP in <FRU Id>
set to faulty because CP ERROR asserted
Probable Cause Indicates that the standby control processor (CP) has been detected as faulty. The High Availability
(HA) feature will not be available. This message occurs every time the other CP reboots, even as
part of a clean warm failover. In most situations, this message is followed by the EM-1047
message, and no action is required for the CP; however, you might want to find out why the failover
occurred.
Recommended
Action
If the standby CP was just rebooted, wait for the error to clear (run slotShow to determine if it has
cleared). Watch for the EM-1047 message to verify that this error has cleared.
If the standby CP continues to be faulty or if it was not intentionally rebooted, check the error logs
on the other CP (using the errDump command) to determine the cause of the error state.
Try reseating the field-replaceable unit (FRU). If the message persists, replace the FRU.
Severity ERROR
EM-1034
Message <timestamp>, [EM-1034], <sequence-number>,, ERROR, <system-name>, <FRU Id> set to
faulty, rc=<return code>.
Probable Cause Indicates that the specified field-replaceable unit (FRU) has been marked as faulty for the specified
reason.
Recommended
Action
Try reseating the FRU.
Run the systemVerification command to verify that the switch does not have hardware problems.
Refer to the Fabric OS Command Reference for more information on this command.
If the message persists, replace the FRU.
Severity ERROR
EM-1035
Message <timestamp>, [EM-1035], <sequence-number>,, ERROR, <system-name>, 2 circuit
paired Power Supplies are faulty, please check the
<Switch side> AC main
switch/circuit to see if it has power.