HP StorageWorks Fabric OS 6.3.1c Release Notes (5697-0509 September 2010 - includes all 6.3.1x versions)
Fixed in Fabric OS 6.3.0
Workaround prior to code change:
Avoid trespassing LUNs using
powerpath.
When running active/passive arrays with powerpath, if a subset of
the LUNs are trespassed, I/O does not properly fail over.
Fixed in Fabric OS 6.3.0
Workaround prior to code change:
Slotpoweroff and slotpower on the
blade to recover.
Encryption blade went in to a faulty (79) state while running rekey
operation in four node encryption group with 200+ LUNs.
Fixed in Fabric OS 6.3.0
During long running CP hafailover and slotpower cycle test, one En-
cryption blade came up faulty indicating BM-BC Heartbeat dead.
Fixed in Fabric OS 6.3.0
Observed CRITICAL while switch was coming up after hareboot on
Viking.
Fixed in Fabric OS 6.3.0
Switchshow lines for FCoE ports should always be in short format.
Fixed in Fabric OS 6.3.0
Workaround prior to code change:
.csv file related changes are
checked-in by the CLI gatekeeper. so
resolving this TR.
If user selects authentication type as "all", in interop modes the default
authentication type is still FCAP between Fabric OS switches.
Fixed in Fabric OS 6.3.0
Fabric watch is allows setting of the Traits and Alarm configuration
even when no alarms are available for all of the classes in WebTools.
Fixed in Fabric OS 6.3.0
The 'swFCPortTable' displays the port statistical data for the logical
port.
Fixed in Fabric OS 6.3.0
Workaround prior to code change:
Slotpoweroff/slotpoweron the blade
or remove the blade and insert back.
Encryption blade turns faulty 21 after firmwaredownload and reboot
of DC SAN Director.
Fixed in Fabric OS 6.3.0
Create 2 access-list with 170 rules in each ACL and apply on 2 ports.
Statistics is not updated for one of the ACL.
Fixed in Fabric OS 6.3.0
MAC access-group is not removed even after executing no mac access-
group in the interface mode.
Fixed in Fabric OS 6.3.0
In interop mode 2, with Default Zone enabled, the user can activate
only 2047 Zones per Zone Set.
Fixed in Fabric OS 6.3.0
Event for change in IDID state on neighboring switch not being posted
to log.
Fixed in Fabric OS 6.3.0
In connUnitLinkTable, for the attribute connUnitLinkConnIdY there is a
mismatch between the PID displayed on the CLI and browser.
Fixed in Fabric OS 6.3.0
Backport code to address various SNMP related issues.
Fixed in Fabric OS 6.3.0
User might observe a Name server related verify on console after
firmware download followed by power cycle on the 4/256 SAN Dir-
ector.
HP StorageWorks Fabric OS 6.3.1c Release Notes 69