HP StorageWorks Fabric OS 5.X Diagnostics and System Error Messages Reference Guide (AA-RVHZB-TE, September 2005)

276 Error messages
Recommended Action
Run the fanShow command to verify that all fans are operating correctly. Replace any deteriorating fan
FRUs.
Run the tempShow command to verify temperature values. If any sensor is too high, monitor the switch.
Try rebooting or power cycling the switch.
Severity
CRITICAL
HLO error messages
HLO-1001
Message
Probable Cause
Indicates that the HLO message was incompatible with the value specified in the FSPF protocol. The HP
StorageWorks switch will not accept FSPF frames from the remote switch.
In the Fabric OS, the HLO dead timeout value is not configurable, so this error can only occur when the HP
StorageWorks switch is connected to a switch from another manufacturer.
Recommended Action
The dead timeout value of the remote switch must be compatible with the value specified in the FSPF
protocol. Refer to the documentation of the other manufacturer's switch to change this value.
Severity
ERROR
HLO-1002
Message
Probable Cause
Indicates that the HLO message was incompatible with the value specified in the FSPF protocol. The HP
StorageWorks switch will not accept FSPF frames from the remote switch.
In the Fabric OS, the HLO timeout value is not configurable, so this error can only occur when the HP
StorageWorks switch is connected to a switch from another manufacturer.
Recommended Action
The HLO timeout value of the remote switch must be compatible with the value specified in the FSPF
protocol. Refer to the documentation of the other manufacturer's switch to change this value.
Severity
ERROR
<timestamp>, [HLO-1001], <sequence-number>,, ERROR, <system-name>,
Incompatible Inactivity timeout <dead timeout> from port <port
number>, correct value <value>
<timestamp>, [HLO-1002], <sequence-number>,, ERROR, <system-name>,
Incompatible Hello timeout <HLO timeout> from port <port number>,
correct value <correct value>