Fabric Watch Administrator's Guide v7.0.0 (53-1002153-01, April 2011)

Fabric Watch Administrator’s Guide 41
53-1002153-01
Fabric monitoring guidelines and default settings
6
Fabric class default settings
Table 4 provides default settings for areas in the Fabric class.
TABLE 4 Fabric class default settings
Area Description Default threshold settings Default alarm
settings
Threshold state
Domain ID changes Monitors forcible
DOMAIN ID changes
Unit: D_ID Changes
Time Base: none
Low: 0
High: 0
Buffer: 0
Below: 0
Above: 0
Informative
Informative
Loss of E_Port Monitors E_Port and
VE_Port status
Unit: Downs
Time Base: none
Low: 0
High: 0
Buffer: 0
Below: 0
Above: 0
Informative
Informative
Fabric logins (FLOGI) Monitors host device
fabric logins
Unit: Logins
Time Base: none
Low: 0
High: 0
Buffer: 0
Below: 0
Above: 0
Informative
Informative
Fabric reconfiguration Monitors
configuration
changes
Unit: Reconfigs
Time Base: none
Low: 0
High: 0
Buffer: 0
Below: 0
Above: 0
Informative
Informative
Segmentation changes Monitors
segmentation
changes
Unit: Segmentations
Time Base: none
Low: 0
High: 0
Buffer: 0
Below: 0
Above: 0
Informative
Informative
Zoning changes Monitors changes to
currently-enabled
zoning configurations
Unit: Zone changes
Time Base: none
Low:0
High:0
Buffer: 0
Below:0
Above: 0
Informative
Informative