Fabric OS MIB Reference v6.4.0 (53-1001768-01, June 2010)
Fabric OS MIB Reference 247
53-1001768-01
connUnitPortTable 1.3.6.1.3.94.1.10
8
Values Possible values are:
• unknown (1)
• other (2)
• temperature (3)
• pressure (4)
• emf (5)
• currentValue (6) Current is a keyword.
• airflow (7)
• frequency (8)
• power (9)
• door (10) Not supported in Fabric OS v2.6.1.
connUnitPortTable 1.3.6.1.3.94.1.10
Generic information on ports for a specific connUnit
NOTE
Information about the GbE ports on a Brocade 7500 or FR4-18i blade is not supported.
connUnitPortEntry 1.3.6.1.3.94.1.10.1
Each entry contains the information for a specific port.
Index connUnitPortUnitId
connUnitPortIndex
connUnitPortUnitId 1.3.6.1.3.94.1.10.1.1
The connUnitId value of the connectivity unit that contains this port.
Same value as connUnitId.
connUnitPortIndex 1.3.6.1.3.94.1.10.1.2
Number of physical ports between 0 and maximum number of system supported ports in the
connectivity unit (internal/embedded, external).
To determine the maximum number of system supported ports, use the SNMP GET command on
swFcPortCapacity.
swSensorType connUnitSensorCharacteristic
1 (temperature) 3 (temperature)
2 (fan) 7 (airflow)
3 (power supply) 9 (power)