Brocade Fabric OS MIB Reference Guide v6.0.0 (53-1000602-01, April 2008)
Fabric OS MIB Reference 151
53-1000602-01
swFCPortIndex 1.3.6.1.4.1.1588.2.1.1.1.6.2.1.1
5
swFCPortIndex 1.3.6.1.4.1.1588.2.1.1.1.6.2.1.1
The switch port index.
Values The physical port number of the switch, plus 1.
The valid values for the Brocade 12000, 24000, and 48000 directors are 0 through maximum
number of ports.
swFCPortType 1.3.6.1.4.1.1588.2.1.1.1.6.2.1.2
The type of ASIC for the switch port.
Values Possible values are:
• stitch (1)
• flannel (2)
• loom (3) (Brocade 2000 series)
• bloom (4) (Valid value for Brocade 3250, 3850, 3900, 12000, 24000)
• rdbloom (5)
• wormhole (6)
• other (7) (Valid value for Brocade 200E, 4012, 4100, 4900, 7500, 7600, and 48000)
• unknown (8)
swFCPortPhyState 1.3.6.1.4.1.1588.2.1.1.1.6.2.1.3
The physical state of the port.
Values Possible values are:
• noCard (1) No card is present in this switch slot.
• noTransceiver (2) No Transceiver module in this port (Transceiver is the generic name for GBIC,
SFP, and so on).
• laserFault (3) The module is signaling a laser fault (defective GBIC).
• noLight (4) The module is not receiving light.
• noSync (5) The module is receiving light but is out of sync.
• inSync (6) The module is receiving light and is in sync.
• portFault (7) The port is marked faulty (defective GBIC, cable, or device).
• diagFault (8) The port failed diagnostics (defective G_Port or FL_Port card or motherboard).
• lockRef (9) Port is locking to the reference signal.