Brocade Fabric OS Message Reference - Supporting Fabric OS v5.3.0 (53-1000437-01, June 2007)
Fabric OS Message Reference 489
53-1000437-01
SULB-1021
83
Probable Cause The BP blade should reboot with the new image, but is still running the old image. This error may
indicate that the new image has not been loaded correctly to the specified blade.
Recommended
Action
Run the slotShow command. If the blade is in a FAULTY state, run the slotPowerOff and
slotPowerOn commands to trigger another firmwareDownload to the blade. If the blade is stuck in
LOADING state, remove and re-insert the blade to trigger another firmwareDownload. If the
problem persists, contact your switch service provider.
Severity ERROR
SULB-1021
Message AUDIT, <timestamp>, [SULB-1021], WARNING, FIRMWARE, <event-initiator-details>,
<event-location>, , Firmware is being downloaded to the blade in slot
<Slot
number>.
Probable Cause Indicates that the firmware is being loaded to the specified blade.
Recommended
Action
Run the firmwareDownloadStatus command to monitor the firmwareDownload progress. After it
finishes, run the firmwareShow command to verify the firmware versions.
Severity WARNING
SULB-1023
Message AUDIT, <timestamp>, [SULB-1023], WARNING, FIRMWARE, <event-initiator-details>,
<event-location>, , The blade in slot
<Slot number> has rebooted during
firmwaredownload.
Probable Cause The error may be caused by an unexpected disruption of the firmwareDownload command, for
example, by powering off and on of the indicated BP blade in the middle of a firmwareDownload.
The error may also be caused by persistent storage hardware failure or by a software error.
Recommended
Action
firmwareCommit will be started automatically after the blade boots up to repair the secondary
partition. If at the end of firmwareCommit, the blade firmware version is still inconsistent with the
active CP firmware, firmwareDownload will automatically be restarted on the blade. Run the
firmwareDownloadStatus command to monitor the progress. If the problem persists, contact your
switch service provider.
Severity WARNING
SULB-1024
Message AUDIT, <timestamp>, [SULB-1024], WARNING, FIRMWARE, <event-initiator-details>,
<event-location>, , Firmware commit has completed on the blade in slot
<Slot
number>.
Probable Cause Indicates that the firmwareCommit operation has completed on the specified blade.