Brocade Fabric OS Message Reference - Supporting Fabric OS v5.3.0 (53-1000437-01, June 2007)
482 Fabric OS Message Reference
53-1000437-01
SULB-1009
83
SULB-1009
Message AUDIT, <timestamp>, [SULB-1009], INFO, FIRMWARE, <event-initiator-details>,
<event-location>, , Firmwaredownload command failed. status: 0x<status code>,
error: 0x<error code>.
Probable Cause Indicates that the firmwareDownload command failed. The additional status code and error code
provide debugging information.
Table lists firmwareDownload status messages and status codes. Some of them will not show up
in this RASLOG message. They are listed for the sake of completeness.
TABLE 9 Status Messages and Status Codes
Status Message Status Code
“firmwareDownload sanity check failed.” 0x30
"Sanity check failed because system is non-redundant." 0x31
“Sanity check failed because firmwareDownload is already in progress.” 0x32
"Sanity check failed because FABRIC OS is disabled on Active CP." 0x33
"Sanity check failed because HAMD is disabled on Active CP." 0x34
“Sanity check failed because firmwareDownload is already in progress.” 0x35
"Sanity check failed because FABRIC OS is disabled on Standby CP." 0x36
"Sanity check failed because HAMD is disabled on Standby CP." 0x37
“firmwareDownload failed on Standby CP.” 0x40
“firmwareDownload failed on Standby CP.” 0x41
“firmwareDownload failed on Standby CP.” 0x42
“firmwareCommit failed on Standby CP.” 0x43
“firmwareDownload failed.” 0x44
“firmwareDownload failed due to IPC error.” 0x50
"Unable to check the firmware version on Standby CP due to IPC error." 0x51
“firmwareDownload failed due to IPC error.” 0x52
“firmwareDownload failed due to IPC error.” 0x53
"Standby CP failed to reboot due to IPC error." 0x54
“firmwareCommit operation failed due to IPC error.” 0x55
"Unable to check the firmware version on Standby CP due to IPC error." 0x56
“Unable to restore the original firmware due to Standby CP timeout.” 0x57
"Standby CP failed to reboot and was not responding." 0x58
"Unable to check the firmware version on Standby CP due to IPC error." 0x59
“Sanity check failed because firmwareDownload is already in progress.” 0x60
“Sanity check failed because firmwareDownload is already in progress.” 0x61
NOT USED 0x62
"System Error." 0x63
"Active CP forced failover succeeded. Now this CP becomes Active." 0x64