Brocade Fabric OS Message Reference - Supporting Fabric OS v5.3.0 (53-1000437-01, June 2007)

450 Fabric OS Message Reference
53-1000437-01
ZONE-1026
77
ZONE-1026
Message <timestamp>, [ZONE-1026], <sequence-number>,, INFO, <system-name>, port <port
number>
Out of CAM entries.
Probable Cause Indicates that the total number of S_ID entries while creating or adding a zone group exceeds the
limit.
Recommended
Action
If hardware zoning enforcement is preferred, edit the zoning database to have zoned PIDs for that
port.
Severity INFO
ZONE-1027
Message <timestamp>, [ZONE-1027], <sequence-number>,, INFO, <system-name>, Zoning
transaction aborted <error reason>. <AD Id>.
Probable Cause Indicates that the zoning transaction was aborted due to a variety of potential errors. The error
reason variable can be one of the following:
Zone Merge Received: The fabric is in the process of merging two zone databases.
Zone Config update Received: The fabric is in the process of updating the zone database.
Bad Zone Config: The new config is not viable.
Zoning Operation failed: A zoning operation failed.
Shell exited: The command shell has exited.
Unknown: An error was received for an unknown reason.
User Command: A user aborted the current zoning transaction.
Switch Shutting Down: The switch is currently shutting down.
Recommended
Action
Many of the causes of this error message are transitory: for example because two admins are
working with the zoning database concurrently. If you receive this error, wait a few minutes and try
again. Verify that no one else is currently modifying the zone database.
Severity INFO